Electronics related fields-Our Products
Photos: coated surfaces
Environments
We provide Material Safety Data Sheet and various reliability test data for you to use the agent with confidence. It has excellent resistance against insulation, weather and heat and conforms to VOC regulation and RoHS compliances.
Costs
A thin application of this Substrate Edge Agent (Alpha) gives a good effect, achieving ultra-low-cost for each substrate.
Options
We provide Automatic Coating Equipment for use in both in-line and off-line.
Reliability test data
Insulation resistance test
After applying the coating agent to a comb-shaped pattern, the insulation resistance is measured during the constant temperature and humidity bias test.
60℃90%RH | |||||||
---|---|---|---|---|---|---|---|
Initial time |
100h | 200h | 300h | 400h | 500h | ||
Edges | 1 up | 4.5E+10 | 1.4E+10 | 2.0E+10 | 1.9E+10 | 2.0E+10 | 3.0E+10 |
1 down | 5.6E+10 | 1.0E+10 | 1.4E+10 | 1.6E+10 | 1.6E+10 | 3.1E+10 | |
Trans parent |
2 up | 5.3E+10 | 1.4E+10 | 1.6E+10 | 2.1E+10 | 5.6E+10 | 4.2E+10 |
2 down | 4.8E+10 | 1.3E+10 | 1.9E+10 | 1.7E+10 | 2.9E+10 | 5.0E+10 |
25℃50%RH | |||
---|---|---|---|
Initial time |
After test |
||
Edges | 1 up | 5.6E+10 | 4.3E+10 |
1 down | 5.6E+10 | 4.8E+10 | |
Trans parent |
2 up | 3.8E+10 | 5.6E+10 |
2 down | 5.0E+10 | 5.0E+10 |
Endurance test
After leaving the sample at 25 ℃ and 50% RH for 500 hours in the constant temperature and humidity chamber, the sample is compared to the one before the test.
T1(℃) | 170 |
---|---|
T2(℃) | 260 |
t1(sec) | 60 |
t2(sec) | 10 |
K1(℃/sec) | 3.0 |
K2(℃/sec) | 1.5 |